Tier 460 Line Cord Receptacle
Motor Surge Protection
Contactor Restart Device
1 - 4
<
>
The Tier 460 Line Cord Receptacle Motor Surge Protection Contactor Restart Device will protect a motor, or an entire system, from power quality events. It runs an onboard surge protection device in series to an onboard contactor restart. The contactor will disconnect the load at predetermined levels, and will reconnect the load at separate predetermined levels automatically. The onboard SPD remains online while the load is disconnected.
This twofold level of protection greatly improves system defenses from power disruption damage.
The 460 SPD family is the ideal solution for protecting industrial systems, motors, and equipment from the damaging effects of transients, phase loss, voltage sags and swells.
The 460 is available with a contactor restart option or a shunt -trip controller
The 460 Motor Surge Protection Contactor Restart features the industry's most advanced metal oxide varistor (MOV) technology.
Its thermally protective, and arc extinguishing, design has a significant advantage when subjected to abnormal over-voltage and high fault current.
The multiple MOV technology allows for the continuation of protection even after a module failure (indicated by our dual color LEDs), giving critical time, under reduced protection, for a repair or replacement (This is covered by our 10 year warranty).
Transient impulses can significantly impact your facility’s power quality, easily disrupting or damaging your process or equipment. While its important to protect against high-energy events, a more frequent, yet often overlooked power quality concern is the damage caused by a phase loss, a temporary voltage sag or a voltage swell condition. Disconnecting your sensitive loads during these longer duration power quality events is the easiest way to safeguard important equipment.
For a higher current rated contactor, or custom specifications, please contact the factory.
We will be happy to accommodate your needs.
Features:
Surge
• Thermally Protected MOV
• Surge Levels Available
• 25 kA/Mode, 50 kA/Phase
• ANSI/UL 1449 4th Edition, CSA
• Sine Wave Tracking: Type 2 only
• Surge Impulse Rated & Tested
Enclosure
•NEMA 4X Indoor/Outdoor Rated
•Polycarbonate Enclosure
•6 Stainless Steel Screw Fasteners
•Enclosure Integrated Mounting Brackets
•Line Cord Receptacle
Monitoring & Control
• Monitors: Under/Over Voltage, Phase
Loss, Imbalance
• Active Load Disconnect & Reset
• User Selectable Controls Over & Under Voltage:
+/- 5, 7.5 10,15, 20, 25%
General Technical Specifications | |
---|---|
Connection Type | Parallel |
Maximum Continuous Operating Voltage | 120V, 150 VAC, All Others 115% |
Short Circuit Rating | 200kAIC |
Protection Modes | All Connected Modes: L-N, L-L, L-G, N-G |
Operating Frequency Range | 47 - 63 Hz |
UL 1449 Location Type | Type 1/Type 2 |
UL 1449 Nominal Discharge Current (In) | 20 kA |
Connection | Line Cord Receptacle |
Status Indication | Dual Color LEDs, Form C, Under/Over Voltage, Phase Loss |
Enclosure | NEMA 4X Indoor/Outdoor rated (Polycarbonate) |
50 Ohm EMI/RFI Attenuation (Only available on Type 2) | 60/40dB Max |
Response Time | <0.5 nanoseconds |
Operating Temperature | -40 C to +75 C |
Operating Humidity | 0% to 95% non-condensing |
Unit Size (Height x Width x Depth) | |
Modular: Up to 150 kA /Mode | 8.695" x 11.25" x 4.000" |
Warranty | 10 Years |
307 Chaumont Dr. │ Endwell, NY 13760 │ Phone: 607-484-1212 │ Toll-Free: 866-748-2357
SOUTHERN TIER TECHNOLOGIES © 2017 - 2022
3